Models

MODELS                                                                                                                  LIVING SQ. FT.              TOTAL SQ. FT.

Esmeralda                                                                                            1.162                                       1.459

SPECIFICATION

STRUCTURAL:
FOOTING; 18”X16” 2.500 psi concrete with (2) continuous #5 steel re-bars count.
FLOORS
:  slab on fill, 4” thick 2.5000 psi concrete, reinforcing w/6x6x10 Ga. WMW. Over 00+ MII visqueen moisture barrier over mechanically compacted fill (termite treated).

MASONRY:  8x8x16 concrete block with poured cells when applicable.
LINTELS:   8”x12” with four (4) continuous #5 includes a truss hurricane anchor system.       Or :   1 course 8”x 8” V block w/ (2) #5 bar, filled w/ 3000 psi concrete on cast-crete lintel w/ (1) #5 bar, filled w/ 3000 psi concrete. W/ a truss hurricane anchor system.
TRUSSES:  Engineered roof trusses-manufactured southern yellow pine w/ galvanized gusset.
SHEETING:   ½ “ thick plywood or osb panel, fastened w/8d ring-shank nails at 6” o.c. at panel edges and 12” o.c. in field roof sheathing.
ROOFING:   Asphalt shingle, use min, 225 lb, fiberglass seal tab over 15 # dry in felt paper.
STEET METAL:   Material galvanize-gauge 26.
INTERIOR STUDS:   2×4 studs at 16 o.c. w/pressure treated bottom plate, w/1/2” x10” grade A-307 anchor bolts at 18” o.c. w/5/16” thk washers, w/ R-11/19 f.g. batt insult.
WALL FINISHES:   ½ “ drywall system,  knock down texture.
STUCCO:   Two (2) coat, skip trowel finish.
FRONT DOORS:   Metal/insulated.
INTERIOR DOORS:   Six (6) panel colonist.
INTERIOR TRIM:   5 ¼ baseboard, 3 ¼ door casing
SLIDING GLASS DOORS:   Tempered.
MARBLE WINDOWSILLS:
GARAGE DOOR:   16’ x 7’ steel door/ hurricane rated/ pre-wired for opener.
CABINETS:   Laminated kitchen w/ 4” back splash, bath vanities w/ marble tops, and laminate medicine cabinets.
MIRRORS:   ¼ “ think plate glass bathrooms.
FINISHED FLOORS:   Carpet on bedrooms and ceramic 18×18 throughout.
WALKS AND DRIVEWAYS:   16’ wide concrete driveway 4” broom finish, 3’ walkways 4” broom finish.
LANAI:   Aluminum/ screened with one door.
Ceramic tiles on guest bath & master shower.
PLUMBING:   Pipes CPVC or PEX per southeast building code, American standards fixtures,
WATER  HEATHER:   40 gallon w/ expansion tank & plastic drain pan. 

esmeralda_floorplanSINKS:   Stainless steel kitchen, and porcelain bowls in water closets.

HOSES BIBS:  Three (3)
TUBS;  Fiber glass.
ELECTICAL:   Wiring, white deco rocker switches and outlets as required.
ELECTICAL FIXTURES:   Exterior Coach Lights,  Entryway flush mount, wired for garage door opener,  kitchen ceiling fan,  hanging dining room fixture.
ELECTICAL:   200 amp service line,  cable and two (2) phone jacks throughout, and two (2) TV jacks. (see contractor for locations)
MECHANICAL:   Condensing units, 2-4 tons 10 seer units.(see contractor for tonnage per model).
MISELLANEOUS:   Upgraded with ceramic top range, built in microwave, side by side refrigerator, dishwasher, garbage disposal.
INSULATION:   R4.2 fi-foil on exterior block walls of living areas. R-11 batts in exterior frame and garage frame wall.  R-19 batts on knee walls adjacent to attic space.  R-19 batts in attic of living areas with proper vents installed.
LANDSCAPE:  Floridian grass, city code landscape package. Automatic sprinkler system / rain gauge.
INSURANCE:   Contractor provide building risk insurance.



La Aurora                                                                                              1.206                                   1.716

SPECIFICATION

STRUCTURAL:
FOOTING; 18”X16” 2.500 psi concrete with (2) continuous #5 steel re-bars count.
FLOORS
:  slab on fill, 4” thick 2.5000 psi concrete, reinforcing w/6x6x10 Ga. WMW. Over 00+ MII visqueen moisture barrier over mechanically compacted fill (termite treated).

MASONRY:  8x8x16 concrete block with poured cells when applicable.
LINTELS:   8”x12” with four (4) continuous #5 includes a truss hurricane anchor system.       Or :   1 course 8”x 8” V block w/ (2) #5 bar, filled w/ 3000 psi concrete on cast-crete lintel w/ (1) #5 bar, filled w/ 3000 psi concrete. W/ a truss hurricane anchor system.
TRUSSES:  Engineered roof trusses-manufactured southern yellow pine w/ galvanized gusset.
SHEETING:   ½ “ thick plywood or osb panel, fastened w/8d ring-shank nails at 6” o.c. at panel edges and 12” o.c. in field roof sheathing.
ROOFING:   Asphalt shingle, use min, 225 lb, fiberglass seal tab over 15 # dry in felt paper.
STEET METAL:   Material galvanize-gauge 26.
INTERIOR STUDS:   2×4 studs at 16 o.c. w/pressure treated bottom plate, w/1/2” x10” grade A-307 anchor bolts at 18” o.c. w/5/16” thk washers, w/ R-11/19 f.g. batt insult.
WALL FINISHES:   ½ “ drywall system,  knock down texture.
STUCCO:   Two (2) coat, skip trowel finish.
FRONT DOORS:   Metal/insulated.
INTERIOR DOORS:   Six (6) panel colonist.
INTERIOR TRIM:   5 ¼ baseboard, 3 ¼ door casing
SLIDING GLASS DOORS:   Tempered.
MARBLE WINDOWSILLS:
GARAGE DOOR:   16’ x 7’ steel door/ hurricane rated/ pre-wired for opener.
CABINETS:   Laminated kitchen w/ 4” back splash, bath vanities w/ marble tops, and laminate medicine cabinets.
MIRRORS:   ¼ “ think plate glass bathrooms.
FINISHED FLOORS:   Carpet on bedrooms and ceramic 18×18 throughout.
WALKS AND DRIVEWAYS:   16’ wide concrete driveway 4” broom finish, 3’ walkways 4” broom finish.
LANAI:   Aluminum/ screened with one door.
Ceramic tiles on guest bath & master shower.
PLUMBING:   Pipes CPVC or PEX per southeast building code, American standards fixtures,
WATER  HEATHER:   40 gallon w/ expansion tank & plastic drain pan.
SINKS:   Stainless steel kitchen, and porcelain bowls in water closets.
HOSES BIBS:  Three (3)
TUBS;  Fiber glass.
ELECTICAL:   Wiring, white deco rocker switches and outlets as required.
ELECTICAL FIXTURES:   Exterior Coach Lights,  Entryway flush mount, wired for garage door opener,  kitchen ceiling fan,  hanging dining room fixture.
ELECTICAL:   200 amp service line,  cable and two (2) phone jacks throughout, and two (2) TV jacks. (see contractor for locations)aurora_floorplanMECHANICAL:   Condensing units, 2-4 tons 10 seer units.(see contractor for tonnage per model).
MISELLANEOUS:   Upgraded with ceramic top range, built in microwave, side by side refrigerator, dishwasher, garbage disposal.
INSULATION:   R4.2 fi-foil on exterior block walls of living areas. R-11 batts in exterior frame and garage frame wall.  R-19 batts on knee walls adjacent to attic space.  R-19 batts in attic of living areas with proper vents installed.
LANDSCAPE:  Floridian grass, city code landscape package. Automatic sprinkler system / rain gauge.
INSURANCE:   Contractor provide building risk insurance.


Otoño                                                                                              1.452                                               2.192otono_color_elevationSPECIFICATION

STRUCTURAL:
FOOTING; 18”X16” 2.500 psi concrete with (2) continuous #5 steel re-bars count.
FLOORS
:  slab on fill, 4” thick 2.5000 psi concrete, reinforcing w/6x6x10 Ga. WMW. Over 00+ MII visqueen moisture barrier over mechanically compacted fill (termite treated).

MASONRY:  8x8x16 concrete block with poured cells when applicable.
LINTELS:   8”x12” with four (4) continuous #5 includes a truss hurricane anchor system.       Or :   1 course 8”x 8” V block w/ (2) #5 bar, filled w/ 3000 psi concrete on cast-crete lintel w/ (1) #5 bar, filled w/ 3000 psi concrete. W/ a truss hurricane anchor system.
TRUSSES:  Engineered roof trusses-manufactured southern yellow pine w/ galvanized gusset.
SHEETING:   ½ “ thick plywood or osb panel, fastened w/8d ring-shank nails at 6” o.c. at panel edges and 12” o.c. in field roof sheathing.
ROOFING:   Asphalt shingle, use min, 225 lb, fiberglass seal tab over 15 # dry in felt paper.
STEET METAL:   Material galvanize-gauge 26.
INTERIOR STUDS:   2×4 studs at 16 o.c. w/pressure treated bottom plate, w/1/2” x10” grade A-307 anchor bolts at 18” o.c. w/5/16” thk washers, w/ R-11/19 f.g. batt insult.
WALL FINISHES:   ½ “ drywall system,  knock down texture.
STUCCO:   Two (2) coat, skip trowel finish.
FRONT DOORS:   Metal/insulated.
INTERIOR DOORS:   Six (6) panel colonist.
INTERIOR TRIM:   5 ¼ baseboard, 3 ¼ door casing
SLIDING GLASS DOORS:   Tempered.
MARBLE WINDOWSILLS:
GARAGE DOOR:   16’ x 7’ steel door/ hurricane rated/ pre-wired for opener.
CABINETS:   Laminated kitchen w/ 4” back splash, bath vanities w/ marble tops, and laminate medicine cabinets.
MIRRORS:   ¼ “ think plate glass bathrooms.
FINISHED FLOORS:   Carpet on bedrooms and ceramic 18×18 throughout.
WALKS AND DRIVEWAYS:   16’ wide concrete driveway 4” broom finish, 3’ walkways 4” broom finish.
LANAI:   Aluminum/ screened with one door.
Ceramic tiles on guest bath & master shower.
PLUMBING:   Pipes CPVC or PEX per southeast building code, American standards fixtures,
WATER  HEATHER:   40 gallon w/ expansion tank & plastic drain pan.
SINKS:   Stainless steel kitchen, and porcelain bowls in water closets.
HOSES BIBS:  Three (3)
TUBS;  Fiber glass.otono_floorplanELECTICAL:   Wiring, white deco rocker switches and outlets as required. 
ELECTICAL FIXTURES:   
Exterior Coach Lights,  Entryway flush mount, wired for garage door opener,  kitchen ceiling fan,  hanging dining room fixture.

ELECTICAL:   200 amp service line,  cable and two (2) phone jacks throughout, and two (2) TV jacks. (see contractor for locations)
MECHANICAL:   Condensing units, 2-4 tons 10 seer units.(see contractor for tonnage per model).
MISELLANEOUS:   Upgraded with ceramic top range, built in microwave, side by side refrigerator, dishwasher, garbage disposal.
INSULATION:   R4.2 fi-foil on exterior block walls of living areas. R-11 batts in exterior frame and garage frame wall.  R-19 batts on knee walls adjacent to attic space.  R-19 batts in attic of living areas with proper vents installed.
LANDSCAPE:  Floridian grass, city code landscape package. Automatic sprinkler system / rain gauge.
INSURANCE:   Contractor provide building risk insurance.


Cristina Isabel                                                                1.482                                          2.242cristina_color_elevationSPECIFICATION

STRUCTURAL:
FOOTING; 18”X16” 2.500 psi concrete with (2) continuous #5 steel re-bars count.
FLOORS
:  slab on fill, 4” thick 2.5000 psi concrete, reinforcing w/6x6x10 Ga. WMW. Over 00+ MII visqueen moisture barrier over mechanically compacted fill (termite treated).

MASONRY:  8x8x16 concrete block with poured cells when applicable.
LINTELS:   8”x12” with four (4) continuous #5 includes a truss hurricane anchor system.       Or :   1 course 8”x 8” V block w/ (2) #5 bar, filled w/ 3000 psi concrete on cast-crete lintel w/ (1) #5 bar, filled w/ 3000 psi concrete. W/ a truss hurricane anchor system.
TRUSSES:  Engineered roof trusses-manufactured southern yellow pine w/ galvanized gusset.
SHEETING:   ½ “ thick plywood or osb panel, fastened w/8d ring-shank nails at 6” o.c. at panel edges and 12” o.c. in field roof sheathing.
ROOFING:   Asphalt shingle, use min, 225 lb, fiberglass seal tab over 15 # dry in felt paper.
STEET METAL:   Material galvanize-gauge 26.
INTERIOR STUDS:   2×4 studs at 16 o.c. w/pressure treated bottom plate, w/1/2” x10” grade A-307 anchor bolts at 18” o.c. w/5/16” thk washers, w/ R-11/19 f.g. batt insult.
WALL FINISHES:   ½ “ drywall system,  knock down texture.
STUCCO:   Two (2) coat, skip trowel finish.
FRONT DOORS:   Metal/insulated.
INTERIOR DOORS:   Six (6) panel colonist.
INTERIOR TRIM:   5 ¼ baseboard, 3 ¼ door casing
SLIDING GLASS DOORS:   Tempered.
MARBLE WINDOWSILLS:
GARAGE DOOR:   16’ x 7’ steel door/ hurricane rated/ pre-wired for opener.
CABINETS:   Laminated kitchen w/ 4” back splash, bath vanities w/ marble tops, and laminate medicine cabinets.
MIRRORS:   ¼ “ think plate glass bathrooms.
FINISHED FLOORS:   Carpet on bedrooms and ceramic 18×18 throughout.
WALKS AND DRIVEWAYS:   16’ wide concrete driveway 4” broom finish, 3’ walkways 4” broom finish.
LANAI:   Aluminum/ screened with one door.
Ceramic tiles on guest bath & master shower.
PLUMBING:   Pipes CPVC or PEX per southeast building code, American standards fixtures,
WATER  HEATHER:   40 gallon w/ expansion tank & plastic drain pan.
SINKS:   Stainless steel kitchen, and porcelain bowls in water closets.
HOSES BIBS:  Three (3)
TUBS;  Fiber glass.Cristina-Isabel_floorplanELECTICAL:   Wiring, white deco rocker switches and outlets as required. 
ELECTICAL FIXTURES:   
Exterior Coach Lights,  Entryway flush mount, wired for garage door opener,  kitchen ceiling fan,  hanging dining room fixture.

ELECTICAL:   200 amp service line,  cable and two (2) phone jacks throughout, and two (2) TV jacks. (see contractor for locations)
MECHANICAL:   Condensing units, 2-4 tons 10 seer units.(see contractor for tonnage per model).
MISELLANEOUS:   Upgraded with ceramic top range, built in microwave, side by side refrigerator, dishwasher, garbage disposal.
INSULATION:   R4.2 fi-foil on exterior block walls of living areas. R-11 batts in exterior frame and garage frame wall.  R-19 batts on knee walls adjacent to attic space.  R-19 batts in attic of living areas with proper vents installed.
LANDSCAPE:  Floridian grass, city code landscape package. Automatic sprinkler system / rain gauge.
INSURANCE:   Contractor provide building risk insurance.


Ana Maria                                                               2.108                                       2.813anamaria_colorSPECIFICATION

STRUCTURAL:
FOOTING; 18”X16” 2.500 psi concrete with (2) continuous #5 steel re-bars count.
FLOORS
:  slab on fill, 4” thick 2.5000 psi concrete, reinforcing w/6x6x10 Ga. WMW. Over 00+ MII visqueen moisture barrier over mechanically compacted fill (termite treated).

MASONRY:  8x8x16 concrete block with poured cells when applicable.
LINTELS:   8”x12” with four (4) continuous #5 includes a truss hurricane anchor system.       Or :   1 course 8”x 8” V block w/ (2) #5 bar, filled w/ 3000 psi concrete on cast-crete lintel w/ (1) #5 bar, filled w/ 3000 psi concrete. W/ a truss hurricane anchor system.
TRUSSES:  Engineered roof trusses-manufactured southern yellow pine w/ galvanized gusset.
SHEETING:   ½ “ thick plywood or osb panel, fastened w/8d ring-shank nails at 6” o.c. at panel edges and 12” o.c. in field roof sheathing.
ROOFING:   Asphalt shingle, use min, 225 lb, fiberglass seal tab over 15 # dry in felt paper.
STEET METAL:   Material galvanize-gauge 26.
INTERIOR STUDS:   2×4 studs at 16 o.c. w/pressure treated bottom plate, w/1/2” x10” grade A-307 anchor bolts at 18” o.c. w/5/16” thk washers, w/ R-11/19 f.g. batt insult.
WALL FINISHES:   ½ “ drywall system,  knock down texture.
STUCCO:   Two (2) coat, skip trowel finish.
FRONT DOORS:   Metal/insulated.
INTERIOR DOORS:   Six (6) panel colonist.
INTERIOR TRIM:   5 ¼ baseboard, 3 ¼ door casing
SLIDING GLASS DOORS:   Tempered.
MARBLE WINDOWSILLS:
GARAGE DOOR:   16’ x 7’ steel door/ hurricane rated/ pre-wired for opener.
CABINETS:   Laminated kitchen w/ 4” back splash, bath vanities w/ marble tops, and laminate medicine cabinets.
MIRRORS:   ¼ “ think plate glass bathrooms.
FINISHED FLOORS:   Carpet on bedrooms and ceramic 18×18 throughout.
WALKS AND DRIVEWAYS:   16’ wide concrete driveway 4” broom finish, 3’ walkways 4” broom finish.
LANAI:   Aluminum/ screened with one door.
Ceramic tiles on guest bath & master shower.
PLUMBING:   Pipes CPVC or PEX per southeast building code, American standards fixtures,
WATER  HEATHER:   40 gallon w/ expansion tank & plastic drain pan.
anamaria_floorplanSINKS:   Stainless steel kitchen, and porcelain bowls in water closets.

HOSES BIBS:  Three (3)
TUBS;  Fiber glass.
ELECTICAL:   Wiring, white deco rocker switches and outlets as required.
ELECTICAL FIXTURES:   Exterior Coach Lights,  Entryway flush mount, wired for garage door opener,  kitchen ceiling fan,  hanging dining room fixture.
ELECTICAL:   200 amp service line,  cable and two (2) phone jacks throughout, and two (2) TV jacks. (see contractor for locations)
MECHANICAL:   Condensing units, 2-4 tons 10 seer units.(see contractor for tonnage per model).
MISELLANEOUS:   Upgraded with ceramic top range, built in microwave, side by side refrigerator, dishwasher, garbage disposal.
INSULATION:   R4.2 fi-foil on exterior block walls of living areas. R-11 batts in exterior frame and garage frame wall.  R-19 batts on knee walls adjacent to attic space.  R-19 batts in attic of living areas with proper vents installed.
LANDSCAPE:  Floridian grass, city code landscape package. Automatic sprinkler system / rain gauge.
INSURANCE:   Contractor provide building risk insurance.


Verano                                                                                      2.195                               3.068verano_color_elevationSPECIFICATION

STRUCTURAL:
FOOTING; 18”X16” 2.500 psi concrete with (2) continuous #5 steel re-bars count.
FLOORS
:  slab on fill, 4” thick 2.5000 psi concrete, reinforcing w/6x6x10 Ga. WMW. Over 00+ MII visqueen moisture barrier over mechanically compacted fill (termite treated).

MASONRY:  8x8x16 concrete block with poured cells when applicable.
LINTELS:   8”x12” with four (4) continuous #5 includes a truss hurricane anchor system.       Or :   1 course 8”x 8” V block w/ (2) #5 bar, filled w/ 3000 psi concrete on cast-crete lintel w/ (1) #5 bar, filled w/ 3000 psi concrete. W/ a truss hurricane anchor system.
TRUSSES:  Engineered roof trusses-manufactured southern yellow pine w/ galvanized gusset.
SHEETING:   ½ “ thick plywood or osb panel, fastened w/8d ring-shank nails at 6” o.c. at panel edges and 12” o.c. in field roof sheathing.
ROOFING:   Asphalt shingle, use min, 225 lb, fiberglass seal tab over 15 # dry in felt paper.
STEET METAL:   Material galvanize-gauge 26.
INTERIOR STUDS:   2×4 studs at 16 o.c. w/pressure treated bottom plate, w/1/2” x10” grade A-307 anchor bolts at 18” o.c. w/5/16” thk washers, w/ R-11/19 f.g. batt insult.
WALL FINISHES:   ½ “ drywall system,  knock down texture.
STUCCO:   Two (2) coat, skip trowel finish.
FRONT DOORS:   Metal/insulated.
INTERIOR DOORS:   Six (6) panel colonist.
INTERIOR TRIM:   5 ¼ baseboard, 3 ¼ door casing
SLIDING GLASS DOORS:   Tempered.
MARBLE WINDOWSILLS:
GARAGE DOOR:   16’ x 7’ steel door/ hurricane rated/ pre-wired for opener.
CABINETS:   Laminated kitchen w/ 4” back splash, bath vanities w/ marble tops, and laminate medicine cabinets.
MIRRORS:   ¼ “ think plate glass bathrooms.
FINISHED FLOORS:   Carpet on bedrooms and ceramic 18×18 throughout.
WALKS AND DRIVEWAYS:   16’ wide concrete driveway 4” broom finish, 3’ walkways 4” broom finish.
LANAI:   Aluminum/ screened with one door.
Ceramic tiles on guest bath & master shower.verano_floorplanWATER  HEATHER:   40 gallon w/ expansion tank & plastic drain pan.
SINKS:
   Stainless steel kitchen, and porcelain bowls in water closets.

HOSES BIBS:  Three (3)
TUBS;  Fiber glass.
ELECTICAL:   Wiring, white deco rocker switches and outlets as required.
ELECTICAL FIXTURES:   Exterior Coach Lights,  Entryway flush mount, wired for garage door opener,  kitchen ceiling fan,  hanging dining room fixture.
ELECTICAL:   200 amp service line,  cable and two (2) phone jacks throughout, and two (2) TV jacks. (see contractor for locations)
MECHANICAL:   Condensing units, 2-4 tons 10 seer units.(see contractor for tonnage per model).
MISELLANEOUS:   Upgraded with ceramic top range, built in microwave, side by side refrigerator, dishwasher, garbage disposal.
INSULATION:   R4.2 fi-foil on exterior block walls of living areas. R-11 batts in exterior frame and garage frame wall.  R-19 batts on knee walls adjacent to attic space.  R-19 batts in attic of living areas with proper vents installed.
LANDSCAPE:  Floridian grass, city code landscape package. Automatic sprinkler system / rain gauge.
INSURANCE:   Contractor provide building risk insurance.


La Primavera                                                                2.456                                        3.227primavera_color_elevationSPECIFICATION

STRUCTURAL:
FOOTING; 18”X16” 2.500 psi concrete with (2) continuous #5 steel re-bars count.
FLOORS
:  slab on fill, 4” thick 2.5000 psi concrete, reinforcing w/6x6x10 Ga. WMW. Over 00+ MII visqueen moisture barrier over mechanically compacted fill (termite treated).

MASONRY:  8x8x16 concrete block with poured cells when applicable.
LINTELS:   8”x12” with four (4) continuous #5 includes a truss hurricane anchor system.       Or :   1 course 8”x 8” V block w/ (2) #5 bar, filled w/ 3000 psi concrete on cast-crete lintel w/ (1) #5 bar, filled w/ 3000 psi concrete. W/ a truss hurricane anchor system.
TRUSSES:  Engineered roof trusses-manufactured southern yellow pine w/ galvanized gusset.
SHEETING:   ½ “ thick plywood or osb panel, fastened w/8d ring-shank nails at 6” o.c. at panel edges and 12” o.c. in field roof sheathing.
ROOFING:   Asphalt shingle, use min, 225 lb, fiberglass seal tab over 15 # dry in felt paper.
STEET METAL:   Material galvanize-gauge 26.
INTERIOR STUDS:   2×4 studs at 16 o.c. w/pressure treated bottom plate, w/1/2” x10” grade A-307 anchor bolts at 18” o.c. w/5/16” thk washers, w/ R-11/19 f.g. batt insult.
WALL FINISHES:   ½ “ drywall system,  knock down texture.
STUCCO:   Two (2) coat, skip trowel finish.
FRONT DOORS:   Metal/insulated.
INTERIOR DOORS:   Six (6) panel colonist.
INTERIOR TRIM:   5 ¼ baseboard, 3 ¼ door casing
SLIDING GLASS DOORS:   Tempered.
MARBLE WINDOWSILLS:
GARAGE DOOR:   16’ x 7’ steel door/ hurricane rated/ pre-wired for opener.
CABINETS:   Laminated kitchen w/ 4” back splash, bath vanities w/ marble tops, and laminate medicine cabinets.
MIRRORS:   ¼ “ think plate glass bathrooms.
FINISHED FLOORS:   Carpet on bedrooms and ceramic 18×18 throughout.
WALKS AND DRIVEWAYS:   16’ wide concrete driveway 4” broom finish, 3’ walkways 4” broom finish.
LANAI:   Aluminum/ screened with one door.
Ceramic tiles on guest bath & master shower.
PLUMBING:   Pipes CPVC or PEX per southeast building code, American standards fixtures,
WATER  HEATHER:   40 gallon w/ expansion tank & plastic drain pan.
SINKS:   Stainless steel kitchen, and porcelain bowls in water closets.
HOSES BIBS:  Three (3)
TUBS;  Fiber glass.primavera_floorplanELECTICAL:   Wiring, white deco rocker switches and outlets as required. 
ELECTICAL FIXTURES:   
Exterior Coach Lights,  Entryway flush mount, wired for garage door opener,  kitchen ceiling fan,  hanging dining room fixture.

ELECTICAL:   200 amp service line,  cable and two (2) phone jacks throughout, and two (2) TV jacks. (see contractor for locations)
MECHANICAL:   Condensing units, 2-4 tons 10 seer units.(see contractor for tonnage per model).
MISELLANEOUS:   Upgraded with ceramic top range, built in microwave, side by side refrigerator, dishwasher, garbage disposal.
INSULATION:   R4.2 fi-foil on exterior block walls of living areas. R-11 batts in exterior frame and garage frame wall.  R-19 batts on knee walls adjacent to attic space.  R-19 batts in attic of living areas with proper vents installed.
LANDSCAPE:  Floridian grass, city code landscape package. Automatic sprinkler system / rain gauge.
INSURANCE:   Contractor provide building risk insurance.


Michelle                                                                                                      2.446                                       3.242michelle_color_elevationSPECIFICATION

STRUCTURAL:
FOOTING; 18”X16” 2.500 psi concrete with (2) continuous #5 steel re-bars count.
FLOORS
:  slab on fill, 4” thick 2.5000 psi concrete, reinforcing w/6x6x10 Ga. WMW. Over 00+ MII visqueen moisture barrier over mechanically compacted fill (termite treated).

MASONRY:  8x8x16 concrete block with poured cells when applicable.
LINTELS:   8”x12” with four (4) continuous #5 includes a truss hurricane anchor system.       Or :   1 course 8”x 8” V block w/ (2) #5 bar, filled w/ 3000 psi concrete on cast-crete lintel w/ (1) #5 bar, filled w/ 3000 psi concrete. W/ a truss hurricane anchor system.
TRUSSES:  Engineered roof trusses-manufactured southern yellow pine w/ galvanized gusset.
SHEETING:   ½ “ thick plywood or osb panel, fastened w/8d ring-shank nails at 6” o.c. at panel edges and 12” o.c. in field roof sheathing.
ROOFING:   Asphalt shingle, use min, 225 lb, fiberglass seal tab over 15 # dry in felt paper.
STEET METAL:   Material galvanize-gauge 26.
INTERIOR STUDS:   2×4 studs at 16 o.c. w/pressure treated bottom plate, w/1/2” x10” grade A-307 anchor bolts at 18” o.c. w/5/16” thk washers, w/ R-11/19 f.g. batt insult.
WALL FINISHES:   ½ “ drywall system,  knock down texture.
STUCCO:   Two (2) coat, skip trowel finish.
FRONT DOORS:   Metal/insulated.
INTERIOR DOORS:   Six (6) panel colonist.
INTERIOR TRIM:   5 ¼ baseboard, 3 ¼ door casing
SLIDING GLASS DOORS:   Tempered.
MARBLE WINDOWSILLS:
GARAGE DOOR:   16’ x 7’ steel door/ hurricane rated/ pre-wired for opener.
CABINETS:   Laminated kitchen w/ 4” back splash, bath vanities w/ marble tops, and laminate medicine cabinets.
MIRRORS:   ¼ “ think plate glass bathrooms.
FINISHED FLOORS:   Carpet on bedrooms and ceramic 18×18 throughout.
WALKS AND DRIVEWAYS:   16’ wide concrete driveway 4” broom finish, 3’ walkways 4” broom finish.
LANAI:   Aluminum/ screened with one door.
Ceramic tiles on guest bath & master shower.
PLUMBING:   Pipes CPVC or PEX per southeast building code, American standards fixtures,
WATER  HEATHER:   40 gallon w/ expansion tank & plastic drain pan.
SINKS:   Stainless steel kitchen, and porcelain bowls in water closets.
HOSES BIBS:  Three (3)
TUBS;  Fiber glass.michelle_floorplanELECTICAL:   Wiring, white deco rocker switches and outlets as required. 
ELECTICAL FIXTURES:   
Exterior Coach Lights,  Entryway flush mount, wired for garage door opener,  kitchen ceiling fan,  hanging dining room fixture.

ELECTICAL:   200 amp service line,  cable and two (2) phone jacks throughout, and two (2) TV jacks. (see contractor for locations)
MECHANICAL:   Condensing units, 2-4 tons 10 seer units.(see contractor for tonnage per model).
MISELLANEOUS:   Upgraded with ceramic top range, built in microwave, side by side refrigerator, dishwasher, garbage disposal.
INSULATION:   R4.2 fi-foil on exterior block walls of living areas. R-11 batts in exterior frame and garage frame wall.  R-19 batts on knee walls adjacent to attic space.  R-19 batts in attic of living areas with proper vents installed.
LANDSCAPE:  Floridian grass, city code landscape package. Automatic sprinkler system / rain gauge.
INSURANCE:   Contractor provide building risk insurance.


Hellen                                                                                                          2.353                                    3.491helen_color_elevationSPECIFICATION

STRUCTURAL:
FOOTING; 18”X16” 2.500 psi concrete with (2) continuous #5 steel re-bars count.
FLOORS
:  slab on fill, 4” thick 2.5000 psi concrete, reinforcing w/6x6x10 Ga. WMW. Over 00+ MII visqueen moisture barrier over mechanically compacted fill (termite treated).

MASONRY:  8x8x16 concrete block with poured cells when applicable.
LINTELS:   8”x12” with four (4) continuous #5 includes a truss hurricane anchor system.       Or :   1 course 8”x 8” V block w/ (2) #5 bar, filled w/ 3000 psi concrete on cast-crete lintel w/ (1) #5 bar, filled w/ 3000 psi concrete. W/ a truss hurricane anchor system.
TRUSSES:  Engineered roof trusses-manufactured southern yellow pine w/ galvanized gusset.
SHEETING:   ½ “ thick plywood or osb panel, fastened w/8d ring-shank nails at 6” o.c. at panel edges and 12” o.c. in field roof sheathing.
ROOFING:   Asphalt shingle, use min, 225 lb, fiberglass seal tab over 15 # dry in felt paper.
STEET METAL:   Material galvanize-gauge 26.
INTERIOR STUDS:   2×4 studs at 16 o.c. w/pressure treated bottom plate, w/1/2” x10” grade A-307 anchor bolts at 18” o.c. w/5/16” thk washers, w/ R-11/19 f.g. batt insult.
WALL FINISHES:   ½ “ drywall system,  knock down texture.
STUCCO:   Two (2) coat, skip trowel finish.
FRONT DOORS:   Metal/insulated.
INTERIOR DOORS:   Six (6) panel colonist.
INTERIOR TRIM:   5 ¼ baseboard, 3 ¼ door casing
SLIDING GLASS DOORS:   Tempered.
MARBLE WINDOWSILLS:
GARAGE DOOR:   16’ x 7’ steel door/ hurricane rated/ pre-wired for opener.
CABINETS:   Laminated kitchen w/ 4” back splash, bath vanities w/ marble tops, and laminate medicine cabinets.
MIRRORS:   ¼ “ think plate glass bathrooms.
FINISHED FLOORS:   Carpet on bedrooms and ceramic 18×18 throughout.
WALKS AND DRIVEWAYS:   16’ wide concrete driveway 4” broom finish, 3’ walkways 4” broom finish.
LANAI:   Aluminum/ screened with one door.
Ceramic tiles on guest bath & master shower.
PLUMBING:   Pipes CPVC or PEX per southeast building code, American standards fixtures,
WATER  HEATHER:   40 gallon w/ expansion tank & plastic drain pan.
helen_floorplanSINKS:   Stainless steel kitchen, and porcelain bowls in water closets.

HOSES BIBS:  Three (3)
TUBS;  Fiber glass.
ELECTICAL:   Wiring, white deco rocker switches and outlets as required.
ELECTICAL FIXTURES:   Exterior Coach Lights,  Entryway flush mount, wired for garage door opener,  kitchen ceiling fan,  hanging dining room fixture.
ELECTICAL:   200 amp service line,  cable and two (2) phone jacks throughout, and two (2) TV jacks. (see contractor for locations)
MECHANICAL:   Condensing units, 2-4 tons 10 seer units.(see contractor for tonnage per model).
MISELLANEOUS:   Upgraded with ceramic top range, built in microwave, side by side refrigerator, dishwasher, garbage disposal.
INSULATION:   R4.2 fi-foil on exterior block walls of living areas. R-11 batts in exterior frame and garage frame wall.  R-19 batts on knee walls adjacent to attic space.  R-19 batts in attic of living areas with proper vents installed.
LANDSCAPE:  Floridian grass, city code landscape package. Automatic sprinkler system / rain gauge.
INSURANCE:   Contractor provide building risk insurance.


Douglas                                                                                                3.363                                      4.227douglas_colorSPECIFICATION

STRUCTURAL:
FOOTING; 18”X16” 2.500 psi concrete with (2) continuous #5 steel re-bars count.
FLOORS
:  slab on fill, 4” thick 2.5000 psi concrete, reinforcing w/6x6x10 Ga. WMW. Over 00+ MII visqueen moisture barrier over mechanically compacted fill (termite treated).

MASONRY:  8x8x16 concrete block with poured cells when applicable.
LINTELS:   8”x12” with four (4) continuous #5 includes a truss hurricane anchor system.       Or :   1 course 8”x 8” V block w/ (2) #5 bar, filled w/ 3000 psi concrete on cast-crete lintel w/ (1) #5 bar, filled w/ 3000 psi concrete. W/ a truss hurricane anchor system.
TRUSSES:  Engineered roof trusses-manufactured southern yellow pine w/ galvanized gusset.
SHEETING:   ½ “ thick plywood or osb panel, fastened w/8d ring-shank nails at 6” o.c. at panel edges and 12” o.c. in field roof sheathing.
ROOFING:   Asphalt shingle, use min, 225 lb, fiberglass seal tab over 15 # dry in felt paper.
STEET METAL:   Material galvanize-gauge 26.
INTERIOR STUDS:   2×4 studs at 16 o.c. w/pressure treated bottom plate, w/1/2” x10” grade A-307 anchor bolts at 18” o.c. w/5/16” thk washers, w/ R-11/19 f.g. batt insult.
WALL FINISHES:   ½ “ drywall system,  knock down texture.
STUCCO:   Two (2) coat, skip trowel finish.
FRONT DOORS:   Metal/insulated.
INTERIOR DOORS:   Six (6) panel colonist.
INTERIOR TRIM:   5 ¼ baseboard, 3 ¼ door casing
SLIDING GLASS DOORS:   Tempered.
MARBLE WINDOWSILLS:
GARAGE DOOR:   16’ x 7’ steel door/ hurricane rated/ pre-wired for opener.
CABINETS:   Laminated kitchen w/ 4” back splash, bath vanities w/ marble tops, and laminate medicine cabinets.
MIRRORS:   ¼ “ think plate glass bathrooms.
FINISHED FLOORS:   Carpet on bedrooms and ceramic 18×18 throughout.
WALKS AND DRIVEWAYS:   16’ wide concrete driveway 4” broom finish, 3’ walkways 4” broom finish.
LANAI:   Aluminum/ screened with one door.
Ceramic tiles on guest bath & master shower.
PLUMBING:   Pipes CPVC or PEX per southeast building code, American standards fixtures,
WATER  HEATHER:   40 gallon w/ expansion tank & plastic drain pan.douglas_floorplanSINKS:   Stainless steel kitchen, and porcelain bowls in water closets.
HOSES BIBS:  Three (3)
TUBS;  Fiber glass.
ELECTICAL:   Wiring, white deco rocker switches and outlets as required.
ELECTICAL FIXTURES:   Exterior Coach Lights,  Entryway flush mount, wired for garage door opener,  kitchen ceiling fan,  hanging dining room fixture.
ELECTICAL:   200 amp service line,  cable and two (2) phone jacks throughout, and two (2) TV jacks. (see contractor for locations)
MECHANICAL:   Condensing units, 2-4 tons 10 seer units.(see contractor for tonnage per model).
MISELLANEOUS:   Upgraded with ceramic top range, built in microwave, side by side refrigerator, dishwasher, garbage disposal.
INSULATION:   R4.2 fi-foil on exterior block walls of living areas. R-11 batts in exterior frame and garage frame wall.  R-19 batts on knee walls adjacent to attic space.  R-19 batts in attic of living areas with proper vents installed.
LANDSCAPE:  Floridian grass, city code landscape package. Automatic sprinkler system / rain gauge.
INSURANCE:   Contractor provide building risk insurance

Villalba                                                                                                    3,570                                            5.692Invierno model

SPECIFICATION

STRUCTURAL:
FOOTING; 18”X16” 2.500 psi concrete with (2) continuous #5 steel re-bars count.
FLOORS
:  slab on fill, 4” thick 2.5000 psi concrete, reinforcing w/6x6x10 Ga. WMW. Over 00+ MII visqueen moisture barrier over mechanically compacted fill (termite treated).
MASONRY:  8x8x16 concrete block with poured cells when applicable.
LINTELS:   8”x12” with four (4) continuous #5 includes a truss hurricane anchor system.       Or :   1 course 8”x 8” V block w/ (2) #5 bar, filled w/ 3000 psi concrete on cast-crete lintel w/ (1) #5 bar, filled w/ 3000 psi concrete. W/ a truss hurricane anchor system.
TRUSSES:  Engineered roof trusses-manufactured southern yellow pine w/ galvanized gusset.
SHEETING:   ½ “ thick plywood or osb panel, fastened w/8d ring-shank nails at 6” o.c. at panel edges and 12” o.c. in field roof sheathing.
ROOFING:   Asphalt shingle, use min, 225 lb, fiberglass seal tab over 15 # dry in felt paper.
STEET METAL:   Material galvanize-gauge 26.
INTERIOR STUDS:   2×4 studs at 16 o.c. w/pressure treated bottom plate, w/1/2” x10” grade A-307 anchor bolts at 18” o.c. w/5/16” thk washers, w/ R-11/19 f.g. batt insult.
WALL FINISHES:   ½ “ drywall system,  knock down texture.
STUCCO:   Two (2) coat, skip trowel finish.
FRONT DOORS:   Metal/insulated.
INTERIOR DOORS:   Six (6) panel colonist.
INTERIOR TRIM:   5 ¼ baseboard, 3 ¼ door casing
SLIDING GLASS DOORS:   Tempered.
MARBLE WINDOWSILLS:
GARAGE DOOR:   16’ x 7’ steel door/ hurricane rated/ pre-wired for opener.
CABINETS:   Laminated kitchen w/ 4” back splash, bath vanities w/ marble tops, and laminate medicine cabinets.
MIRRORS:   ¼ “ think plate glass bathrooms.
FINISHED FLOORS:   Carpet on bedrooms and ceramic 18×18 throughout.
WALKS AND DRIVEWAYS:   16’ wide concrete driveway 4” broom finish, 3’ walkways 4” broom finish.
LANAI:   Aluminum/ screened with one door.
Ceramic tiles on guest bath & master shower.
PLUMBING:   Pipes CPVC or PEX per southeast building code, American standards fixtures,
WATER  HEATHER:   40 gallon w/ expansion tank & plastic drain pan.

Invierno model 2SINKS:   Stainless steel kitchen, and porcelain bowls in water closets.
HOSES BIBS:  Three (3)
TUBS;  Fiber glass.
ELECTICAL:   Wiring, white deco rocker switches and outlets as required.
ELECTICAL FIXTURES:   Exterior Coach Lights,  Entryway flush mount, wired for garage door opener,  kitchen ceiling fan,  hanging dining room fixture.
ELECTICAL:   200 amp service line,  cable and two (2) phone jacks throughout, and two (2) TV jacks. (see contractor for locations)
MECHANICAL:   Condensing units, 2-4 tons 10 seer units.(see contractor for tonnage per model).
MISELLANEOUS:   Upgraded with ceramic top range, built in microwave, side by side refrigerator, dishwasher, garbage disposal.
INSULATION:   R4.2 fi-foil on exterior block walls of living areas. R-11 batts in exterior frame and garage frame wall.  R-19 batts on knee walls adjacent to attic space.  R-19 batts in attic of living areas with proper vents installed.
LANDSCAPE:  Floridian grass, city code landscape package. Automatic sprinkler system / rain gauge.
INSURANCE:   Contractor provide building risk insurance.Mirelis 2

SPECIFICATION

STRUCTURAL:
FOOTING; 18”X16” 2.500 psi concrete with (2) continuous #5 steel re-bars count.
FLOORS
:  slab on fill, 4” thick 2.5000 psi concrete, reinforcing w/6x6x10 Ga. WMW. Over 00+ MII visqueen moisture barrier over mechanically compacted fill (termite treated).
MASONRY:  8x8x16 concrete block with poured cells when applicable.
LINTELS:   8”x12” with four (4) continuous #5 includes a truss hurricane anchor system.       Or :   1 course 8”x 8” V block w/ (2) #5 bar, filled w/ 3000 psi concrete on cast-crete lintel w/ (1) #5 bar, filled w/ 3000 psi concrete. W/ a truss hurricane anchor system.
TRUSSES:  Engineered roof trusses-manufactured southern yellow pine w/ galvanized gusset.
SHEETING:   ½ “ thick plywood or osb panel, fastened w/8d ring-shank nails at 6” o.c. at panel edges and 12” o.c. in field roof sheathing.
ROOFING:   Asphalt shingle, use min, 225 lb, fiberglass seal tab over 15 # dry in felt paper.
STEET METAL:   Material galvanize-gauge 26.
INTERIOR STUDS:   2×4 studs at 16 o.c. w/pressure treated bottom plate, w/1/2” x10” grade A-307 anchor bolts at 18” o.c. w/5/16” thk washers, w/ R-11/19 f.g. batt insult.
WALL FINISHES:   ½ “ drywall system,  knock down texture.
STUCCO:   Two (2) coat, skip trowel finish.
FRONT DOORS:   Metal/insulated.
INTERIOR DOORS:   Six (6) panel colonist.
INTERIOR TRIM:   5 ¼ baseboard, 3 ¼ door casing
SLIDING GLASS DOORS:   Tempered.
MARBLE WINDOWSILLS:
GARAGE DOOR:   16’ x 7’ steel door/ hurricane rated/ pre-wired for opener.
CABINETS:   Laminated kitchen w/ 4” back splash, bath vanities w/ marble tops, and laminate medicine cabinets.
MIRRORS:   ¼ “ think plate glass bathrooms.
FINISHED FLOORS:   Carpet on bedrooms and ceramic 18×18 throughout.
WALKS AND DRIVEWAYS:   16’ wide concrete driveway 4” broom finish, 3’ walkways 4” broom finish.
LANAI:   Aluminum/ screened with one door.
Ceramic tiles on guest bath & master shower.
PLUMBING:   Pipes CPVC or PEX per southeast building code, American standards fixtures,
WATER  HEATHER:   40 gallon w/ expansion tank & plastic drain pan.

MirelisSINKS:   Stainless steel kitchen, and porcelain bowls in water closets.
HOSES BIBS:  Three (3)
TUBS;  Fiber glass.
ELECTICAL:   Wiring, white deco rocker switches and outlets as required.
ELECTICAL FIXTURES:   Exterior Coach Lights,  Entryway flush mount, wired for garage door opener,  kitchen ceiling fan,  hanging dining room fixture.
ELECTICAL:   200 amp service line,  cable and two (2) phone jacks throughout, and two (2) TV jacks. (see contractor for locations)
MECHANICAL:   Condensing units, 2-4 tons 10 seer units.(see contractor for tonnage per model).
MISELLANEOUS:   Upgraded with ceramic top range, built in microwave, side by side refrigerator, dishwasher, garbage disposal.
INSULATION:   R4.2 fi-foil on exterior block walls of living areas. R-11 batts in exterior frame and garage frame wall.  R-19 batts on knee walls adjacent to attic space.  R-19 batts in attic of living areas with proper vents installed.
LANDSCAPE:  Floridian grass, city code landscape package. Automatic sprinkler system / rain gauge.
INSURANCE:   Contractor provide building risk insurance.[/col]